| Model
|
DN
|
Class
|
Over
load Flowrate (m3/h) |
Nominal
Flowrate (m3/h) |
Transitional Flowrate (m3/h)
|
Min
Flowrate (m3/h) |
Min
Reading(m3) |
Max
Reading(m3) |
|
Remote-reading water meter |
15 |
B |
3 |
1.5
|
0.12
|
0.03
|
0.0001 |
99999 |
| 20 |
B |
5 |
2.5
|
0.2
|
0.05
|
| 25 |
B |
7 |
3.5
|
0.28
|
0.07
|
| Working
Condition |
Water
temperature ≤ 35 (cold) Water temperature ≤ 90(hot)
Working Pressure ≤ 1MPa |
Feature
|
Sensors of reed with high stability and immunity to
disturbance enable a long life span. Keep all technical
items. Sustain the numeral display function Unique
design and advanced tests ensure a secure transmission.
Minimum distance between connected meter and a data
collector:100m Applicable to various kinds of data
collector Two kinds of meter body: Steel and Brass.
|
Main Technical Data
|
1. Pulse
Constant: 60 pulses per m 3 water Connecting wire length:
30cm Stainless steel jacket can be chosen as an option to
protect pulse line. Error of Indication: When Qmin ≤ Q<
Qt δ: 5% Qt≤Q≤Qmax, δ: 2% |